High Sensitive ELISA Kit for Interleukin 28B (IL28B)
IFNL3; Interferon,Lambda 3; Cytokine Zcyto22
- Product No.HEC028Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- All
- Human
- Mouse
- Rat
- Cavia
- Rabbit
- Simian
- Caprine
- Ovine
- Equine
- Bovine
- Porcine
- Gallus
- Canine
- Others
- Multi-species
- Pan-species
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range1.56-100pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.64pg/mL.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- DownloadInstruction Manual
- UOM48T96T96T*596T*1096T*100
- FOBUS$ 539 For more details, please contact local distributors!US$ 770 For more details, please contact local distributors!US$ 3465 For more details, please contact local distributors!US$ 6545 For more details, please contact local distributors!US$ 53900 For more details, please contact local distributors!
Specificity of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)
This assay has high sensitivity and excellent specificity for detection of High Sensitive Interleukin 28B (IL28B).No significant cross-reactivity or interference between High Sensitive Interleukin 28B (IL28B) and analogues was observed.
Recovery of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)
Matrices listed below were spiked with certain level of recombinant High Sensitive Interleukin 28B (IL28B) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Interleukin 28B (IL28B) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 91-101 | 95 |
EDTA plasma(n=5) | 83-95 | 91 |
heparin plasma(n=5) | 80-95 | 79 |
Precision of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Interleukin 28B (IL28B) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Interleukin 28B (IL28B) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10%>10%>Inter-Assay: CV<12%>12%>
Linearity of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Interleukin 28B (IL28B) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 98-105% | 96-104% | 89-104% | 99-105% |
EDTA plasma(n=5) | 86-98% | 91-99% | 80-91% | 78-105% |
heparin plasma(n=5) | 96-104% | 92-99% | 84-105% | 93-103% |
Stability of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)
1. Prepare all reagents, samples and standards;2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;4. Aspirate and wash 3 times;5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;6. Aspirate and wash 5 times;7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the High Sensitive ELISA Kit for Interleukin 28B (IL28B)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Interleukin 28B (IL28B). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Interleukin 28B (IL28B). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Interleukin 28B (IL28B), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Interleukin 28B (IL28B) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
ELISA / CLIA Experiment Service
INCREMENT SERVICES
Single-component Reagents of Assay KitLysis Buffer Specific for ELISA / CLIAQuality Control of ELISA / CLIADisease Model Customized ServiceTGFB1 Activation ReagentReal Time PCR Experimental Service
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
APC028Hu01 | Active Interleukin 28B (IL28B) | Cell culture; Activity Assays. |
LAC028Hu81 | FITC-Linked Polyclonal Antibody to Interleukin 28B (IL28B) | WB; IHC; ICC; IF. |
LAC028Hu71 | Biotin-Linked Polyclonal Antibody to Interleukin 28B (IL28B) | WB; IHC; ICC. |
MAC028Hu22 | Monoclonal Antibody to Interleukin 28B (IL28B) | WB; IHC; ICC; IP. |
HEC028Hu | High Sensitive ELISA Kit for Interleukin 28B (IL28B) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEC028Hu | ELISA Kit for Interleukin 28B (IL28B) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCC028Hu | CLIA Kit for Interleukin 28B (IL28B) | Chemiluminescent immunoassay for Antigen Detection. |